Calibration Baths, Hydra Series Oil Baths
|
|
|

Liquid Calibration Baths, -80°C to 300°C (572°F) in Three Models
-
Parallel Tube Action — Liquid flows up the rear volume of the bath and down the working volume. This action creates very small vertical and axial gradients. Enabling the smallest overall uncertainties
-
Circular Design — The circular design eliminates cold corners in tank-shaped baths
- Heating — All heating is outside the container. By using a large area nickel foil heater the complete bath wall is heated uniformly
- Cooling — The cooling is built-in and also surrounds the calibration volume creating a low temperature ambient in which the heater can function efficiently
- Wider Temperature Range — A unique system removes the coolant from around the calibration volume above ambient and lets the bath heat up to 125°C (121°C is a key sterilization temperature)
-
Stability — Better than ±0.030°C over the complete temperature range
798 Hydra Datasheet
|
|
 |
|
|
|
|
 |
|
Dryblock Calibrators, Fast Cal Series Drywells
|
|
|

Available in 4 models: Low & HTM2010 -35°C to 140°C, Medium 30°C to 350°C and High 35°C to 650°C
- Lightweight (15 lbs.)
- Fast response, high stability.
- Incorporate a built-in Insert holder for ultra fast changes and calibration cycles. (Medium and High Fast-Cal models)
- Standard PC interface. Extra software is available for automatic calibration.
- Fast-Cal design is modern and complies with all the relevant requirements and directives which are applicable.
- 5 point NIST traceable calibration certificate included.
- Mains power variance immunity standard on all Isotech dry block calibrators.
FastCal Datasheet
|
|
 |
|
|
|
|
 |
|
Dry Block Calibrators, Gemini High Capacity blocks
|
|
|

High Capacity Dry Block Calibrators
30°C to 700°C (1292°F) Display to Block Accuracy Better than ±0.5°C
- Calibrate Whole Calibration Loop --Using a heat source rather than an electrical simulator a test instrument and probe can be calibrated as a system.
- High Capacity Block -- Large Calibration volume for many sensors and low loading errors.
- Two Operating Ranges -- Fast response from ambient to 550°C (1022°F) or ambient to 700°C (1292°F)
- Simple To Use -- Outstanding Value for Money!
|
|
 |
|
|
|
|
 |
|
ISOCAL 6 Calibrators, Europa, Venus & Calisto Models
|
|
|

3 Models to choose from covering -45ºC to 250ºC (482ºF)
Isocal 6 (Standard Volume) Datasheet
|
|
 |
|
|
|
|
 |
|
ISOCAL 6 Calibration Baths, Hyperion & Drago Models
|
|
|

Temperature range covering -25°C to 250°C (482°F), in two models
- 2.5” (65mm) Diameter Calibration Volume
- Portable Liquid Bath for high accuracy calibration of awkward shaped sensors
- Convertible for Dry Block Operation and more
- Calibrates All Sensor Types
- Windows Software and PC Interface
- Available in the Hyperion 936 and Drago 934 Models
Isocal 6 (Large Volume) Datasheet
|
|
 |
|
|
|
|
 |
|
MEDUSA - P.O.T.T.S Temperature Calibrator
|
|
|

3 Zone Block Calibrator or Automated Fixed Points
30°C to 700°C (1202°F)
Medusa Product Spec Sheet
|
|
 |
|
|
|
|
 |
|
Oceanus 6 - P.O.T.T.S Temperature Calibrator
|
|
|

Block Calibrator or Automated Fixed Points
-25°C to 140°C (282°F) 10" Deep for Long Sensors Optional Inserts for Black Body & Liquid Bath
- Universal Input Temperature Indicator included in S Model to allow for programming of up to five correction points
- ITS-90 Fixed Points can be used with the Gallium and Triple Point of Water Fixed Point Cells
- Dry or Liquid Bath
- Windows Software and PC Interface
- High Capacity Deep Block for Very Long Thermometers
- Ideal for Laboratory Comparison and Fixed-Point Calibrations
|
|
 |
|
|
|
|
 |
|
ISIS is the World's First -100°C Dry Block Calibrator
|
|
|

Minimum temperature of -100°C (-148°C)
- No hazardous or expensive liquids.
- Stability of 0.02°C at -90°C.
- 20,000 hours of testing, equal to 10 years of use.
- Patented technology.
- Uses flexible heat pipe to transfer energy.
- C.E. approved.
- UKAS/ILAC, NIST Traceable Certification availiable.
ISIS Datasheet
|
|
 |
|
|
|
|
 |
|
JUPITER 650 - High Temperature Dry Block Calibrator
|
|
|

Temperature Range of 30°C to 650°C (1202°F)
- Accuracy: ±0.3°C (display to block)
- Uniformity: Use of a specialized high conductivity block results in superior uniformity
-
Wide Operating Range: Fast response up to 650°C (1202°F) ideal for field use
-
Simple To Use and Outstanding Value
-
Calibrate to entire loop by using a heat source rather than an electrical simulator, a test instrument and sensor can be calibrated as a system
Jupiter 650 Datasheet
|
|
 |
|
|
|
|
 |
|
PEGASUS 1200 - High Temperature Dry Block Calibrator
|
|
|

Temperature Range of 150°C to 1200°C (2192°F)
- Accuracy: ±3.0°C (display to block)
- Stability: Better than ±0.3°C over the range
-
Unique Accessories: Infrared calibration and fast cool down attachments
-
Simple To Use and Outstanding Value
-
Perfect for high tempertaure switches
Pegasus 1200 Datasheet
|
|
 |