You are here: Home > Products > Infrared Calibrators

Blackbody Furnaces and Infrared Temperature Calibrators

Sort By:
Page of 1
Isotech Blackbody Source, Model 989 Model 989 - Human Body Temperature Black Body Source

Human Body Temperature IR Thermometer Calibrator
Temperature Range of 20°C to 50°C (122°F)

  • Accuracy: 0.2°C (Combined accuracy & stability)
  • Emissivity: 0.97 ±0.2
  • Multiple Mounting Options
  • Ideal for Calibration of IR thermometers around human body temperature and integration into fever detection system
Model 989 Blackbody Source Datasheet

Base Price: $2,495.00
991 Tympanic Thermometer Checker 991 Tympanic Thermometer Checker

Tympanic Thermometer Calibrator
Temperature Range of 20°C to 50°C (122°F)

  • Cost-Effective: A fraction of the cost of a full laboratory setup
  • Portable: Easy to use in clinics and field settings, with compact equipment
  • User-Friendly: No specialized training needed, perfect for quality control and checks
Model 991 Tympanic Thermometer Calibrator Datasheet

Base Price: $2,495.00
Isotech, Blackbody Calibrator, 970 PEGASUS R Blackbody Source PEGASUS R 970 - High Temperature Blackbody Source

High Temperature IR Thermometer Calibrator
Temperature Range of 150°C to 1200°C (2192°F)

  • Emissivity: 0.995
  • Ideal for: Raytek ST, MX & CI Series thermometers
  • Includes External Reference Probe
  • Accepts Fixed Point Cells
  • NIST Certificate: For the built-in Indicator and supplied probe
Model 970 Pegasus R Datasheet

Base Price: $15,453.00
Blackbody Calibrator, GEMINI R - Medium Temperature Blackbody Source GEMINI R - Medium Temperature Black Body Source

Medium Temperature IR Thermometer Calibrator
Temperature Range of 30°C to 550°C (1022°F)
Ideal for Raytek ST, MX & CI Series thermometers

  • Emissivity: 0.995
  • Stability: >±0.1°C
  • Includes External Reference Probe
  • Accepts Fixed Point Cells
  • NIST Certificate: For the built-in Indicator and supplied probe
Model 976 Gemini R Datasheet

Base Price: $10,017.00
Isotech Blackbody Source, Model 988 Low Temperature Calibrator Model 988 - Human Body Temperature Black Body Source

Low Temperature IR Thermometer Calibrator
Temperature Range of 20°C to 45°C (113°F)

  • Accuracy: 0.2°C (Combined accuracy & stability)
  • Emissivity: 0.97 ±0.2
  • Controller Resolution: 0.01°C
  • Ideal for Calibration of IR thermometers around human body temperature
  • NIST Certificate: For the built-in Indicator
Model 988 Blackbody Source Datasheet

Base Price: $4,441.00
Isotech, Primary Infrared Calibration Source OBERON R - Black Body Source for High Temperature

Black Body Fixed Point System
Temperature Range of 450°C to 1090°C (1994°F)
Advanced Heat Pipe Technology

  • Emissivity: >0.995
  • Stability: ±0.05°C
  • Sodium heat pipe for exceptionally low temperature gradient
  • High temperature furnace for aluminum, silver, gold or copper Black Body Fixed-Point Cells
  • Cavity 300mm Deep
Oberon R Blackbody Data Sheet Oberon R Blackbody Data Sheet

Isotech, Quick Cal Hand Held Infrared Calibrator QuickCal Blackbody - Hand Held Infrared Calibrator

Economical IR Calibration
Temperature Range of 35°C to 350°C (662°F)

  • Accuracy: ±0.5
  • Emissivity: >0.99
  • Stability: ±0.2°C
  • Handheld Source, Ideal for Field Use
  • Low Cost
QuickCal R Datasheet

Base Price: $3,406.00
Isotech, Spherical Blackbody Calibration Source Cyclops Model 878

Our most stable Black Body Source
Temperature Range of 150°C to 1300°C (2372°F)

  • Stability: ±0.1°C
  • Emissivity: > 0.999
  • Wide Temperature Range
  • Spherical Black Body Source
  • Can be Adapted for Thermocouple Calibration 877 Saturn
Model 878 Cyclops Datasheet

Isotech, Infrared Calibrator with 0.95 Emissivity Grey Body Source - Model 975

Temperature Range of 50°C to 350°C (662°F)
Emissivity of 0.95

  • Accuracy: ±2
  • Stability: ±0.2°C
  • Very Portable
  • Fast Response Times
  • Ideal for Raytek MT Series thermometers
Model 975 Greybody Source Datasheet

Isotech Primary Blackbody Primary Calibration Source Medusa R - Black Body Primary Source

Temperature Range of 30°C to 550°C (1022°F)
Advanced Heat Pipe Technology

  • Emissivity: >0.995
  • Stability: ±0.1°C
  • Accuracy: to ±0.05°C
  • Accepts Isotech Primary Blackbody Cells
  • Heating Time 45 Minutes
Model 999 Medusa R Datasheet

Isotech, Blackbody Fixed Point Cells, intrinsic Infrared standards Black Body Fixed Point Cells

ITS-90 Primary sources
Fixed-Point Cells for Black Body Sources

  • Primary Standard Fixed Points
  • Unique Patented Design
  • High Accuracy
  • Black Body Radiation Sources
  • Long, Flat Plateau
  • ITS 90 Fixed Points
Black Body Fixed Point Cells Datasheet

Blackbody Calibrator, HYPERION R - Low Temperature Blackbody Source HYPERION R - Low Temperature Black Body

Temperature Range of -20°C to 125°C (257°F)
Can Expand to use Fixed Point Cells

  • Emissivity: 0.995
  • Stability: ±0.1°C
  • Ideal for Raytek ST, MX & CI Series thermometers
  • 50mm Cavity Diameter
  • Low Temperature Radiation Pyrometer Primary Source
Model 982 Hyperion R Datasheet

Base Price: $10,744.00