ISOCAL 6 Calibrators (Europa, Venus & Calisto Models)
|
|
|

-45°C to 250°C (482°F)
Available in the Venus 2140, Calisto 2240 and Europa 6 Models- 6 calibrators in 1
- Liquid baths, infrared, dryblock & ITS-90 fixed points all in one
- 35mm Calibration Volume
- ≤0.3°C Dry Block Accuracy
- Fast Heating and Cooling Time
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
JUPITER 650 - High Temperature, Dry Block Calibrator
|
|
|

30°C to 650°C (1202°F)
- Display to Block Accuracy ±0.3°C
- Calibrate Whole Calibration Loop.Using a heat source rather than an electrical simulator, a test instrument and sensor can be calibrated as a system
- Excellent Temperature Uniformity. Careful design and research allows use of a high conductivity heater block
- Wide Operating Range. Fast response from ambient to 650°C (1202°F)ideal for field use
- Simple To Use and Outstanding Value
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
PEGASUS 1200 - Very High Temperature Dry Block Calibrator
|
|
|

150°C to 1200°C (2192°F)
Display to Block Accuracy Better than ±3°C
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
QUICKCAL - Hand-Held Dry Block Temperature Calibrator
|
Our Price: $1,590.00
|
|
|

30°C to 350°C (650°F)
- Wide temperature range: 30°C to 350°C (662°F)
- Fast calibration of temperature sensors: Nine minutes to reach temperature
- Better accuracy: 0.4°C to 0.2°C, using comparison techniques
- Light, compact, and portable
- Interchangeable inserts: To suit different diameter sensors
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
ISOCAL6 Calibration Baths, Hyperion & Drago Models
|
|
|

-50°C to 250°C (482°F)
Available in Drago and Hyperion Models- 2.5 (65mm) Diameter Calibration Volume
- Portable Liquid Bath for high accuracy calibration of awkward shaped sensors
- Convertible for Dry Block Operation and more
- Calibrates All Sensor Types
- Windows Software and PC Interface
- Available in the Hyperion 936 and Drago 394 Models
Isocal 6 (Large Volume) Product Spec Sheet
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
ISIS is the World's First -100°C Dry Block Calibrator
|
|
|

Minimum temperature of -100°C (-148°C)
- No hazardous or expensive liquids.
- Stability of 0.02°C at -90°C.
- 20,000 hours of testing, equal to 10 years of use.
- Patented technology.
- Uses flexible heat pipe to transfer energy.
- C.E. approved.
- UKAS/ILAC, NIST Traceable Certification availiable.
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
Dryblock Calibrators, Fast Cal Series Drywells
|
|
|

-35°C to 650°C Available in 4 models: Low and HTM2010 -35°C to 140°C, Medium 30°C to 250°C and High 35°C to 650°C
- Lightweight (15 lbs.)
- Fast response, high stability.
- Incorporate a built-in Insert holder for ultra fast changes and calibration cycles. (Medium and High Fast-Cal models)
- Standard PC interface. Extra software is available for automatic calibration.
- Fast-Cal design is modern and complies with all the relevant requirements and directives which are applicable.
- 5 point NIST traceable calibration certificate included.
- Mains power variance immunity standard on all Isotech dry block calibrators.
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
Dry Block Calibrators, Gemini High Capacity blocks
|
|
|

High Capacity Dry Block Calibrators
30°C to 700°C (1292°F) Display to Block Accuracy Better than ±0.5°C
- Calibrate Whole Calibration Loop --Using a heat source rather than an electrical simulator a test instrument and probe can be calibrated as a system.
- High Capacity Block -- Large Calibration volume for many sensors and low loading errors.
- Two Operating Ranges -- Fast response from ambient to 550°C (1022°F) or ambient to 700°C (1292°F)
- Simple To Use -- Outstanding Value for Money!
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
MEDUSA - P.O.T.T.S Temperature Calibrator
|
|
|

3 Zone Block Calibrator or Automated Fixed Points
30°C to 700°C (1202°F)
Medusa Product Spec Sheet
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
OCEANUS 6 - P.O.T.T.S Temperature Calibrator
|
|
|

Block Calibrator or Automated Fixed Points
-25°C to 140°C (282°F) 10" Deep for Long Sensors Optional Inserts for Black Body & Liquid Bath
- Universal Input Temperature Indicator included in S Model to allow for programming of up to five correction points
- ITS-90 Fixed Points can be used with the Gallium and Triple Point of Water Fixed Point Cells
- Dry or Liquid Bath
- Windows Software and PC Interface
- High Capacity Deep Block for Very Long Thermometers
- Ideal for Laboratory Comparison and Fixed-Point Calibrations
|
|
 |
 |
 |
 |